■ 제품필수정보
제조사 |
Honeywell |
제조사품명 |
HAFBLF0050CAAX5 |
간략설명 |
Honeywell HAF Series Amplified Airflow Sensor for Dry Gas, 0 sccm Min, 50 sccm Max |
■ 제품사양
Media Monitored = Dry Gas Device
타입 = Amplified Minimum Flow Rate = 0 sccm Maximum Flow Rate = 50 sccm Supply Voltage = 5 V dc Pipe Diameter Range = Maximum of 5.35 mm Connection
타입 = Tubing Maximum Pressure = 25psi Material = High Temperature Polymer
최소 작동 온도 = -20°C
최대 작동 온도 = +70°C
Current 등급 = 20 mA
시리즈 = HAF Honeywell Zephyr??HAF
시리즈 ??High Accuracy ±50 SCCM to ±750 SCCM. Honeywell Zephyr??HAF
시리즈 sensors provide a digital interface for monitoring airflow over specified full-scale flow and compensated temperature ranges. The thermally isolated heater and temperature sensing elements help these sensors provide a fast response to air or gas flow. Zephyr sensors are designed to measure mass flow of air and other non-corrosive gases. Standard flow ranges are available at ±50, ±100, ±200, ±400 or ±750 sccm. Custom flow ranges are also available. The sensors are fully calibrated and temperature compensated with an onboard Application Specific Integrated Circuit (ASIC). The HAF
시리즈 is compensated over the temperature range of 0°C to 50°C and operates across a temperature range of -20°C to 70°C. The state-of-the-art ASIC-based compensation provides digital (I2C) outputs with a response time of 1 ms. These sensors operate on the heat transfer principle to measure mass airflow. They consist of a microbridge Microelectronic and Microelectromechanical System (MEMS) with temperature-sensitive resistors deposited with thin films of platinum and silicon nitride. The MEMS sensing die is located in a precise and carefully designed airflow channel to provide repeatable response to flow. Zephyr sensors provide the customer with enhanced reliability, high accuracy, repeatable measurements and the ability to customise sensor options to meet many specific application needs. The combination of rugged housings with a stable substrate makes these products robust. They are designed and manufactured according to ISO 9001 standards. Features and Benefits. Total error band as low as ±0.25%. Fast response time. Wide range of airflows. Customisable flow ranges. High sensitivity when flow is low. Linear output provides more intuitive sensor signal. High stability reduces errors due to thermal effects. Low-pressure drop typically improves patient comfort in medical applications. Product Application Information. MEDICAL. Anaesthesia delivery machines. Ventricular assist devices (heart pumps). Hospital diagnostics (spectrometry, gas chromatography). Nebulisers. Oxygen concentrators. Patient monitoring systems (respiratory monitoring). Sleep apnea machines. Spirometers. Ventilators. Laparoscopy. INDUSTRIAL. Air-to-fuel ratio. Analytical instrumentation (spectrometry, chromatography). Fuel cells. Gas leak detection. VAV system on HVAC systems. Gas meters. HVAC filters