상품이미지
  •  상품이미지

MPN : 3114

PR Electronics 3100 Series Isolated Universal Converter, 16.8 ??31.2V dc, Universal Input, Current, Voltage
  • 브랜드

    PR Electronics

  • 무원상품코드

    M012152000585

  • 타입별
    EA
  • 주문가능수량

    59

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 381,774원

  • 수량단가2 : 5개 ~ 314,198원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 PR Electronics
제조사품명 3114
간략설명 PR Electronics 3100 Series Isolated Universal Converter, 16.8 ??31.2V dc, Universal Input, Current, Voltage

■ 제품사양

Module
타입 = Universal Signal Converter Input Signal
타입 = Universal Output Signal
타입 = Current, Voltage Supply Voltage = 16.8 ??31.2V dc Input Range = 0 ??12 V dc, 0 ??20mA Output Range = 0 ??10 V dc, 0 ??20mA Hazardous Area Certification = ATEX
장착형태 = DIN Rail Mount Operating Temperature Range = -25 ??+70°C
최소 작동 온도 = -25°C 3114 Multifunctional Converter. PR 3114 isolated multifunction converter for conversion of linear resistance variation to a standard analogue current / voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer. The PR 3000 series is a family of compact, fast, and easy to use 6 mm signal conditioners with exceptional performance and EMC immunity for dedicated applications ??including indoor and outdoor environments with wide temperature fluctuations. Designed and rated to operate between 25 ?C to +70 ?C, making these devices a good choice in applications where the ambient temperature changes greatly. These high-performance devices utilize our innovative microprocessor technology to provide high base accuracy, low power consumption, and maximum protection against error due to electromagnetic noise. Features and Benefits. High basic 0.05% accuracy in all available signal ranges. 2.5 kVAC isolation and have excellent noise immunity. NAMUR NE21 burst A criteria. Transmits rapid changes in process measurements to PLC/DCS for fast and accurate monitoring of critical signals. Low temperature coefficient better than 0.01% / °C in a wide -25 to +70°C ambient temperature range for precise measurements. Long term accuracy better than 0.1% / 3 years with no need for re-calibration. Installation in ATEX Ex zone 2 / IECEx Zone 2 / FM division 2. DIP-switch programming. Re-calibration is not needed after changing the DIP-switch range settings. Just change the DIP-switch, cycle the power to the unit and obtain the new, pre-calibrated I/O range. HART programming is enabled for selected devices. Mounting. Devices can be mounted both vertically and horizontally with no air gap separation required. The devices snap onto a power rail or DIN rail and are easily detached by lifting the bottom lock. High level of isolation. Safe galvanic isolation of 2.5 kVAC provides high noise immunity and prevents ground loops for accurate delivery of the process signal to your control system. Device status indicators. A front LED indicates device status, e.g. an error in the set-up, sensor or hardware. Over voltage- / polarity protection. All terminals can withstand up to ±31.2 VDC and are protected against incorrect supply wiring to ensure safe, error-free installation.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지