상품이미지
  •  상품이미지

MPN : IR-750-EUR

Amprobe IR-750 Infrared Thermometer, -50°C Min, +1550°C Max, °C and °F Measurements
  • 브랜드

    Amprobe

  • 무원상품코드

    M012145010408

  • 타입별
    EA
  • 주문가능수량

    품 절

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 671,874원

  • 수량단가2 : 5개 ~ 552,952원


총금액
(VAT 별도)

  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Amprobe
제조사품명 IR-750-EUR
간략설명 Amprobe IR-750 Infrared Thermometer, -50°C Min, +1550°C Max, °C and °F Measurements

■ 제품사양

Absolute Maximum Temperature Measurement = +1550°C Temperature Scale = Centigrade, Fahrenheit Distance to Spot Ratio = 50:1 Emissivity = 0.1 ??1.0 Model Number p = IR-750 Resolution = 0.1 °C, 0.2 °C, 1 °C Data Storage = Yes Response Time = 250 ms Length = 147mm Width = 57mm
높이 = 183mm
무게 = 345g Software CD, USB cable, K-type thermocouple probe, carrying bag, hard carrying case, battery and instruction manual. Amprobe IR-750 Infrared Thermometer. The IR-700 series are high performance diagnostic tools designed for HVAC/R, industrial, electrical, automotive, fire prevention and quality control applications. Reliable and accurate, this thermometer has an adjustable emissivity for measurement on a wide range of materials and surfaces. A powerful laser thermometer, it has a single point laser, which produces accurate targeting, with a distance to spot ratio of 50:1. Each thermometer in this series has a dual LCD display with backlight, making readings easy in darker environments. This mutli-use device can be used as a non-contact thermometer and/or a contact thermometer with a thermocouple input option. Features and Benefits:. USB Interface Thermocouple input Stores up to 99 data points Adjustable emissivity -50°C to 1550°C temperature range 19mm minimum spot size. FAQ's. Are infrared thermometers dangerous?. Infrared thermometers are not harmful, they do not emit radiation, only measure it like a digital camera. How accurate are infrared thermometers?. The majority of IR thermometers have a measurement error specification, which shows their best accuracy. The surface being measured can also affect accuracy. Reflective objects result in lower measurements than the actual temperature, whilst non-reflective surfaces give higher measurement. The emissivity of a surface is how effective it is at emitting energy as thermal radiation, as such some IR thermometers have adjustable emissivity settings. Distance to spot ratio is also essential in providing accurate temperature measurements, if an infrared thermometer is too close to its target area, heat can build up in the device. This can give false readings or damage the temperature sensors, therefore it is essential to always follow a manufacturers guidelines.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-05-27
3
답변 완료
2024-05-13
4
답변 완료
2024-04-16
5
답변 완료
2023-12-08
6
답변 완료
2023-11-21
상품정보이미지