MPN : A9F54350

Schneider Electric Acti 9 iC60H MCB, 3P Poles, 50A Curve C, 440V AC, 100 ??133V DC, 10 kA Breaking Capacity, MCB
  • 브랜드

    Schneider Electric

  • 무원상품코드

    M012143007723

  • 타입별
    EA
  • 주문가능수량

    25

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 146,756원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Schneider Electric
제조사품명 A9F54350
간략설명 Schneider Electric Acti 9 iC60H MCB, 3P Poles, 50A Curve C, 440V AC, 100 ??133V DC, 10 kA Breaking Capacity, MCB

■ 제품사양

Number of Poles = 3P
Current 등급 = 50A Tripping Characteristics =
타입 C Rated AC Voltage = 440 V, 12 ??133 V, 220 ??240 V, 380 ??415V Rated DC Voltage = 100 ??133V
시리즈 = iC60H Breaking Capacity at Maximum Voltage Rating = 10 kA Circuit Breaker
타입 = MCB Mounting Style = DIN Rail Mount Width = 54mm Length = 85mm Depth = 78.5mm Better World Product = Yes Terminal Contact
타입 = Screw Acti9 iC60H MCB 3 Pole. iC60H series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2. ACTi 9 is fully tested, approved and certified by national and international third parties. It guarantees that your installation is safe and compliant with all relevant safety standards which demonstrates to your customers that you use industry-approved materials and best practices. These MCBs are normally used for high inductive loads where switching surges are high. Providing essential protection in industrial and commercial buildings, these miniature circuit breakers work especially well in polluted environments and networks. Benefits ; Features. VisiSafe guarantees the downstream circuit is always safe regardless of overvoltage conditions, even in the most demanding environments; the green strip indicates the safe position of contacts. VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime. Benefits and Features. Downstream circuit is always safe Class-2 insulation: ensures continuous protection for both operators and unqualified persons. Insulated terminals (IP20) Highly durable with robust connections that provide twice the standard tightening torque Provide greater continuity of service thanks to VisiTrip Double clip for dismounting with comb busbar in place. Downstream circuit is always safe Class-2 insulation: ensures continuous protection for both operators and unqualified persons. Insulated terminals (IP20) Highly durable with robust connections that provide twice the standard tightening torque Provide greater continuity of service thanks to VisiTrip Double clip for dismounting with comb busbar in place. Standards. IEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar Installations. In the UK traditionally known as miniature circuit breakers (MCB ??s). IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar Installations. In the UK traditionally known as moulded case circuit breakers (MCCB ??s) and also air circuit breakers (ACB ??s). Q: What exactly does a miniature circuit breaker do?. A: It protects wires from overloads and short-circuits. For overload protection the temperature of a bimetal, through which the current passes is decisive. If the nominal current??the current the circuit breaker is designed for??rises slightly, the bimetal heats up to a greater extent and, after a certain period of time, this causes the switching mechanism to trip. Today MCBs are installed in all our homes, offices and other buildings, protecting the electrical wires from damage. They have the advantage that they can be manually reset without having to replace wire as in the case of the traditional fuse. The MCBs have either a button or lever that can be flicked to reset it. They are used instead of fuses due to their convenience and improved safety features. Q: What is the differences in the Tripping Curves B, C, and D?. A: Curve B: Tripping: 3 to 5 times the rated current. Applications: protection of generators, persons, very long cables Curve C: Tripping: 5 to 10 times the rated current Applications: protection of circuits and general applications Curve D: Tripping: 10 to 14 times the rated current Applications: protection of high surge circuits, welders, transformers and motors

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지