상품이미지
  •  상품이미지
  •  상품이미지

MPN : CN50A24-5

TDK-Lambda DC-DC Converter, 5V dc/ 10A Output, 14.4 ??36 V dc Input, 50W, Surface Mount
  • 브랜드

    TDK-Lambda

  • 무원상품코드

    M012141003519

  • 타입별
    EA
  • 주문가능수량

    품 절

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 190,065원

  • 수량단가2 : 5개 ~ 184,375원

  • 수량단가3 : 10개 ~ 178,653원

  • 수량단가4 : 25개 ~ 174,854원

  • 수량단가5 : 50개 ~ 171,070원


총금액
(VAT 별도)

  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 TDK-Lambda
제조사품명 CN50A24-5
간략설명 TDK-Lambda DC-DC Converter, 5V dc/ 10A Output, 14.4 ??36 V dc Input, 50W, Surface Mount

■ 제품사양

Output Voltage = 5V dc Input Voltage Range = 14.4 ??36 V dc Power Rating = 50W Input Voltage Nominal = 24 V dc Output Current = 10A
장착형태 = Surface Mount Isolated = Yes Number of Outputs = 1 Isolation Voltage = 500V dc Depth = 57.9mm Load Regulation = 40mV Minimum Temperature = -40°C UL60950-1, CSA60950-1, EN60950-1, CE LVD. TDK-Lambda CN-A 24VDC
시리즈, 100W 24Vdc Input, Quarter Brick Railway Isolated DC-DC Converters. CN-A 24VDC series, 50/100W 24Vdc input, railway isolated DC-DC converters with a compact pin-out design that uses less PCB space and a wide input voltage range of 14.4 to 36Vdc. These CN-A 24VDC series 50 W and 100W railway isolated DC-DC converters are compliant with the applicable railway standards and are designed for harsh environments, meeting the shock and vibration requirements of IEC61373 Category 1 Class B. True useable power from -40 to +100°C without derating can be provided by these railway isolated DC-DC converters which are base-plate cooled, they can also offer up to 88% efficiency and up to 20A useable output current. Typical uses for these CN-A 24VDC series railway isolated DC-DC power modules include battery powered railway systems such as rolling stock and fixed installations, power plants and customer power supplies. Wide 14.4 - 36Vdc input range to EN50155/IEC60571 Compliant with applicable railway standards Shock and vibration compliant to IEC61373 Category 1 Class B Full power from -40 to +100?C without derating (covers TX class for Railway) Base plate cooled High efficiency of up to 88% Up to 20A useable output current 3kVac input/output isolation Remote sensing and remote on/off functions Overvoltage and overcurrent protection Undervoltage lockout function (UVLO) Protects battery against deep discharges Compact size: 36.8 x 12.7 x 57.9mm

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지