MPN : 118523 XDP4/I(400V50HZ,440V60H

Eaton 4 kW DOL Starter, 400 V ac, IP65
  • 브랜드

    Eaton

  • 무원상품코드

    M011886002168

  • 타입별
    EA
  • 주문가능수량

    5

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 393,683원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Eaton
제조사품명 118523 XDP4/I(400V50HZ,440V60H
간략설명 Eaton 4 kW DOL Starter, 400 V ac, IP65

■ 제품사양

Power Rating = 4 kW Motor Starter
타입 = DOL Voltage Rating = 400 V ac IP Rating = IP65 Number of Poles = 3P Motor Starter Functionality = Automatic Additional Features = Disconnect Switch Included
전체 길이 = 200mm Enclosure = Yes Overall Width = 120mm Overall Depth = 160mm
시리즈 = XDP IEC/EN 60529, DIN 43660, EN 50262. FLC figures quoted are maximum, other overload ratings can be used dependant on FLC rating. EATON XDP DOL Starter
시리즈 with Isolator. Providing reliability and long operating life, these 'direct-on-line' starters are totally insulated with IP65 protection. Capable of high numbers of operations, these starters are constructed from standard components meaning they are very easy to maintain. Fitted with AC-3 rated triple pole contactor, AC-3 rated triple pole switch disconnector and on and off pushbuttons, these devices also allow for 3 padlocks for additional safety. All starters in this range are wired to accept EATON overload relays for overload protection, also available from RS components to be purchased separately. 4 ; 5.5kW models = H200 x W120 x D160mm, 7.5 ; 11kW models = H240 x W160 x D160mm. Features and Benefits:. Fitted with metric knockouts Easy maintenance Complies with IEE regulations 16th edition on isolation and switching Glass fibre reinforced polycarbonate casing. Applications:. Used for starting 3 phase induction motors, direct on line starters are regularly used in industrial applications such as conveyor belts, compressors and small water pumps. What is the difference between dol and star delta starters?. Both devices are used to start induction motors however, where partial voltage is applied to each winding of a star delta starter, a DOL has 100% voltage applied. This also applies to the current, a star delta uses one-third of the starting current that a DOL does. Direct on line starters are the most common and simplest starting method, within a motor start-up they also provides the lowest temperature rise. Star delta starters allow for starting the motor at a lower voltage, making them suitable for high inertias.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지