상품이미지
  •  상품이미지

MPN : 777949

Pilz PSWZ X1P Series Single/Dual-Channel Speed/Standstill Monitoring Safety Relay, 24 ??240V ac/dc, 2 Safety
  • 브랜드

    Pilz

  • 무원상품코드

    M011865010778

  • 타입별
    EA
  • 주문가능수량

    21

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 948,617원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Pilz
제조사품명 777949
간략설명 Pilz PSWZ X1P Series Single/Dual-Channel Speed/Standstill Monitoring Safety Relay, 24 ??240V ac/dc, 2 Safety

■ 제품사양

Supply Voltage = 24 ??240V ac/dc Number of Channels = 1, 2 Safety Contacts = 2 Function = Speed/Standstill Monitoring Auxiliary Contacts = 1 Range = PNOZ X Safety Category ISO 13849-1 = 3 PL ISO 13849-1 = e SIL IEC 61508 = 3 Terminal
타입 = Screw Length = 94mm VDE 0113; EN 60204-1; IEC 204-1. BG, UL, CUL. PSWZX1P Safety Relay by PILZ. The PSWZX1P range of safety relays from PILZ offers you safety and performance all in one. The PSWZX1P offers you different modes of operation such as single or dual channel switches. Suitable specifically for operating your safe standstill machinery or tools that are deemed dangerous or hazardous to health. Features and benefits:. DIN rail mounted with screw terminals LED display that offers you the following measures: - Supply voltages - Standstill on Channel 1 / 2 - Switch status - Fault signal if simultaneity time is exceeded Semiconductor output signal (input for reset function): - Error - Switch status Measure inputs for single or three-phase motors Measuring voltage is selectable Feedback loop is in operation Plug in connection terminals is possible. Safety features:. Relays K1 ; K2 are interlocked specifically designed so that the unit cannot be switched back on in the case of contact welding or an open circuit (ensuring your safety at all times) The unit will monitor and measure and look out for an open circuit. If the circuit does open, the unit will immediately switch itself off to prevent hazards The standstill motor which is unique to the PSWZ X1P prevents the plant from being enabled, in the following cases: - Power supply failure - Component failure - Measuring circuits are open circuit - Coil deflect / open circuit. Applications:. B>Safe standstill monitoring ??this is the units main purpose and is specifically designed for safe standstill where areas of operation such as plants have dangerous machinery or tools in use. Safe standstill monitoring is only detected on power free measuring circuits. Any residual voltages, induced voltages or drives with in the position control will prevent the relay from its main function so take this into consideration when in use. Technical safety parameters:. EN 60204-1 EN 62061 EN ISO 13849-1 EN ISO 14119 VDE 0113-1

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-05-27
3
답변 완료
2024-05-13
4
답변 완료
2024-04-16
5
답변 완료
2023-12-08
6
답변 완료
2023-11-21
상품정보이미지