상품이미지
  •  상품이미지

MPN : XPSMP11123

Schneider Electric XPS MP Series Single-Channel Safety Mat/Edge, Safety Switch/Interlock Safety Relay, 24V dc, 6 Safety
  • 브랜드

    Schneider Electric

  • 무원상품코드

    M011850007717

  • 타입별
    EA
  • 주문가능수량

    품 절

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 780,389원


총금액
(VAT 별도)

  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Schneider Electric
제조사품명 XPSMP11123
간략설명 Schneider Electric XPS MP Series Single-Channel Safety Mat/Edge, Safety Switch/Interlock Safety Relay, 24V dc, 6 Safety

■ 제품사양

Supply Voltage = 24V dc Number of Channels = 1 Safety Contacts = 6 Function = Safety Mat/Edge, Safety Switch/Interlock Auxiliary Contacts = 3 Reset Method = Automatic, Monitored Range = Preventa Safety Category ISO 13849-1 = 4 PL ISO 13849-1 = e SIL IEC 61508 = 3 Configurable = Yes Terminal
타입 = Screw Clamp Performance Level = e BG, UL, CSA. IEC 204-1; EN 292; EN 418; EN 60204-1; EN 954-1 EN 1088. XPS MP, Configurable Safety Relay, 15 Selectable Functions. From Schneider Electric we offer you the Preventa XPS range of Safety relays (safety modules) providing the solution and answer to monitoring safety relay functions. The relays include redundancy principle micro-pressor technology providing you with advanced functionality. There are various safety relay models to choose from, including removeable terminal block versions, allowing easy selection of a module to monitor a safety functions. XPS-MP offers a simple solution for all safety applications and reduces the number of ordering references needed by combining 15 pre-determined functions that are all certified Designed to monitor 2 safety functions independently, choose from; emergency stop, protective door locking, 2 hand control buttons, safety mats or type 4 light curtains 3N/O safety contacts per function providing extensive safety control function capability 3 solid state outputs for sending status information to a PLC Suitable for use with safety control systems to all categories of EN954-1 12 LED indication and 3 buttons on front face for quick and easy setup Monitoring of start button or automatic starting Compact 45mm housing Number of input channels: 1 or 2. XPSMP11123 Preventa Safety Relay Module Features and Benefits. ;ul> ;li>Safety controller with pre-defined function. ;/li> ;li>ZPSMP Module / Relay. ;/li> ;li>2 Independent functions. ;/li> ;li>Safety category 4 (maximum) to EN/IEC 60954-1. ;/li> ;li>Captive screw clamp terminals. ;/li> ;li>5 W maximum power consumption. ;/li> ;li>24 V (Uc) control circuit voltage. ;/li> ;li>100 Ohm line resistance. ;/li> ;li>3 NO, volt free relays per function (6-NO total). ;/li> ;li>3 solid state outputs. ;/li> ;li>Breaking capacity 20 MA at 24 V static output circuit (1.5 A at 24 V DC-13 constant 50 ms repay output). ;/li> ;li>10 MA minimum output current relay output. ;/li> ;li>17 V Minimum output voltage relay output. ;/li> ;li>30 Ms input open response time. ;/li> ;li>12 LEDs. ;/li> ;li>35 mm DIN rail mounting. ;/li> ;li>Depth 114 mm,
높이 99 mm, Width 45 mm,
무게 0.32 kg. ;/li> ;/ul>. Functions. ;ul> ;li>Configuration 0: functions disabled (factory setting). Configuration 1: emergency stop monitoring 1-channel wiring, category 2. Configuration 10: enabling grip switch monitoring (3-position switch), category 4. Configuration 11: sensing mat and edges monitoring, category 3. Configuration 12: sensing mat and edges monitoring, category 3. Configuration 13: relay output safety light curtain monitoring, category 4. Configuration 14: coded magnetic switch monitoring, category 4. Configuration 15: coded magnetic switch monitoring, category 4. ;/li> ;/ul>. ;ul> ;li>Configuration 2: emergency stop monitoring 1-channel wiring category 2. ;/li> ;li>Configuration 3: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4. Configuration 4: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4. Configuration 5: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4. Configuration 6: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4. Configuration 7: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4. Configuration 8: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4. Configuration 9: guard monitoring for injection presses and blowing machines, category 4. ;/li> ;/ul>. Start
타입. ;ul> ;li>Automatic or unmonitored (configuration 1), Automatic or unmonitored (configuration 10), Automatic or unmonitored (configuration 11), Automatic or unmonitored (configuration 14), Automatic or unmonitored (configuration 3,) Automatic or unmonitored (configuration 5), Automatic or unmonitored (configuration 7), Monitored (configuration 12,) Monitored (configuration 13), Monitored (configuration 15), Monitored (configuration 2), Monitored (configuration 4), Monitored (configuration 6), Monitored (configuration 8), Monitored (configuration 9). ;/li> ;/ul>. Protection. ;ul> ;li>IP20 (terminals), IP40 (enclosure). ;/li> ;/ul>