■ 제품필수정보
제조사 |
Burkert |
제조사품명 |
143491 |
간략설명 |
Burkert Solenoid Valve 143491, 2 port(s) , NO, 24 V dc, 1/4in |
■ 제품사양
Supply Voltage = 24 V dc Number of Ports = 2 Connection = 1/4 in G Female Connection Size = 1/4in Default Valve Position = NO Suitable Applications = Compressed Air, Gas, Hydraulic Oil, Neutral Liquid
타입 = 2/2 Orifice Diameter = 2.5mm Body Material = Brass Maximum Working Pressure = 8 bar Operating Temperature Range = -10 ??+55 °C
최소 작동 온도 = -10°C
최대 작동 온도 = +55°C Flow Factor Kv = 0.16m³/h Burkert Solenoid ValveThe Burkert 0280 series 1/4inG female solenoid valve has a supply voltage of 24VDC. This 2-port NO position valve with a servo diaphragm has a compact design with NBR seal. The valve is normally open by spring action assisted by the fluid pressure. When de-energized, the media is exhausted to atmosphere via the pilot operator. When energized, the space above the servo diaphragm is exhausted via the pilot valve, the diaphragm is lifted by the fluid pressure to close the valve. Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left-hand side of the diagram describes the operation of the valve when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and is described on the right-hand side of the diagram. The 3 / 2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2 / 2-way valves as two ways. The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications indicates the appropriate connections and pressure capabilities when an alternative circuit function is required.Features and BenefitsMaximum working pressure is 8bar Flow factor(Kv) is 0.16m³/h High flow rate Operating temperature is between -10°C and 55°C Power consumption is 8W Solenoid epoxy encapsulation efficiently dissipates the heat generated by the coil The supply voltage is 24VDCApplicationsCircuit function B for air or gases (consult for use with liquids) Fire protection installations Irrigation systems Laundries Machine tools Neutral gases and liquids Sanitary applications Varnishing technologyCertificationsIP65 rated