상품이미지
  •  상품이미지

MPN : 088911 PKZM0-1-T

Eaton 0.63 ??1 A Motor Protection Circuit Breaker, 690 V ac
  • 브랜드

    Eaton

  • 무원상품코드

    M011731004743

  • 타입별
    EA
  • 주문가능수량

    6

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 143,139원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Eaton
제조사품명 088911 PKZM0-1-T
간략설명 Eaton 0.63 ??1 A Motor Protection Circuit Breaker, 690 V ac

■ 제품사양


Current 등급 = 0.63 ??1 A Motor Protection Component = Circuit Breaker Supply Voltage = 690 V ac
시리즈 = PKZM 0
전체 길이 = 93mm Overall Width = 45mm Overall Depth = 76mm Voltage Rating = 690 V ac Breaking Capacity = 150 kA PKZMO accessories can be used allowing additional functions. Transformer Protection Switches, PKZM0-T. Eaton's reliable and robust transformer protective circuit breakers are the perfect solution for your motor protection needs, providing protection from electrical faults such as an overload of high voltages, short circuits or relay shutdowns. Down-time of machinery can be detrimental to a business and its operations, Eaton's PKZM0-*-T transformer protection range of circuit breakers has been created and designed to act as an intermediary between your devices, protecting vital equipment in the event of unforeseen incidents. This reduces the amount of downtime of machinery to enable operations to continue running smoothly. The PKZM0 motor protection circuit breakers and the PKZM0-*-T transformer protective circuit breakers are matched to the DIL contactor series making the ideal configuration or motor starter combinations. This transformer and motor protection range of circuit breakers has a short circuit breaking capacity rated to 150 kA up to 12 A and 50kA up to 32 A. Accessories including auxiliary contacts, trip indicating auxiliary contacts, voltage release and shunt trips can be installed without tools and greatly reduce installation time. Features ; Benefits. DIN rail mounted, mechanically reset protection devices. Transformer short circuit and overload protection The short circuit release is set to 20 x I ;sub>u ;/sub>, so even transformers that have high inrush currents have protection Rotary handle for ease of trip indication after a fault has occurred Rated operational voltage 690V Trip-fault indication Phase failure sensitive 93 x 45 x 76mm (H x W x D). How do I select the right Motor Protection Circuit Breaker?. MPCBs are more critical now than ever. Most infrastructures now rely on a motor behind the scenes to power critical uninterruptible systems such as heating, ventilation and cooling. These systems are vital in ensuring business continues as usual, therefore must be protected against overcurrent's, thermal overloads and similar problems. To select the right MPCB, consider the systems you and your business rely upon. Checking the features and benefits of each MPCB will prove invaluable when deciding what critical infrastructure you wish to protect.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지