상품이미지
  •  상품이미지
  •  상품이미지

MPN : 1926539

RS PRO Temperature Transmitter Linear Resistance, RTD, Thermocouple, Voltage Input, 8 ??30 V dc
  • 브랜드

    RS PRO

  • 무원상품코드

    M010997007743

  • 타입별
    EA
  • 주문가능수량

    품 절

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 359,055원


총금액
(VAT 별도)

  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 RS PRO
제조사품명 1926539
간략설명 RS PRO Temperature Transmitter Linear Resistance, RTD, Thermocouple, Voltage Input, 8 ??30 V dc

■ 제품사양

Input
타입 = Linear Resistance, RTD, Thermocouple, Voltage Supply Voltage = 8 ??30 V dc Diameter = 44 mm Minimum Temperature Input = -200°C Maximum Temperature Input = 850°C
최소 작동 온도 = -40°C
최대 작동 온도 = +85°C Depth = 20.2mm Hazardous Area Certification = ATEX, IECEx RS PRO 2-Wire Programmable Transmitter with HART Protocol RS PRO introduces a brilliant range of programmable temperature transmitters. These temperature transmitters provide unrivalled input versatility for virtually any thermocouple and bipolar mV signals. The input sensor redundancy function maintains process availability and safety in the event of primary sensor failure. An alert via HART can be used to allow scheduling of maintenance on the faulty sensor. Features and Benefits RTD, TC, Ohm, or mV input Extremely high measurement accuracy HART 5 protocol Galvanic isolation For DIN form B sensor head mounting Applications It is very important in many industries to ensure that temperatures are reliable and accurate to ensure that products are protected from different temperature ranges for example: Control rooms Production lines Furnaces Chemical processing plants Factories Power generation plants Technical Characteristics Linearized temperature measurement with Pt100..Pt1000, Ni100..Ni1000, or TC sensor. Difference or average temperature measurement of 2 resistance or TC sensors. Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level sensors. Amplification of a bipolar mV signal to a standard 4..20 mA current signal. Connection of up to 15 transmitters to a digital 2-wire signal with HART communication. Within a few seconds the user can program the transmitter to measure temperatures within all ranges defined by the norms. The RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection. The transmitter has been designed according to strict safety requirements and is therefore suitable for application in SIL installations. Continuous check of vital stored data for safety reasons. Sensor error detection according to the guidelines in NAMUR NE89. Mounting / Installation For DIN form B sensor head mounting. How Do Temperature Transmitters Work? Temperature transmitters are electrical components that connect a temperature sensor, most commonly, a thermocouple, RTD or thermistor to a measurement or control device such as a loop controller, PLC, DCS, PC, data logger etc. Temperature transmitters isolate, amplify, filter noise, linearise and convert the input signal from the sensor it is connected to, for example - a thermocouple, it then transmits a standardised output signal to the control device of your choice like a data logger. Why RS PRO? RS PRO is our own brand range and brings you a wide range of high-quality, great value products offering you more choice. Trusted by engineers all over the world, every part of every RS PRO product has been rigorously tested against demanding industry standards; they??re only given the RS PRO seal of approval if we??re confident of their exceptional quality, which means you can be confident too.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지