상품이미지
  •  상품이미지

MPN : 6333B1A

PR Electronics 6300 Temperature Transmitter Linear Resistance, RTD Input, 8 ??30 V dc
  • 브랜드

    PR Electronics

  • 무원상품코드

    M010553005955

  • 타입별
    EA
  • 주문가능수량

    2

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 284,950원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 PR Electronics
제조사품명 6333B1A
간략설명 PR Electronics 6300 Temperature Transmitter Linear Resistance, RTD Input, 8 ??30 V dc

■ 제품사양

Input
타입 = Linear Resistance, RTD Supply Voltage = 8 ??30 V dc Diameter = 23.5 (Width) mm Minimum Temperature Input = -200°C Maximum Temperature Input = 850°C
최소 작동 온도 = -40°C
최대 작동 온도 = +85°C
시리즈 = 6300 Depth = 104mm Hazardous Area Certification = ATEX 6333B 2-Wire Programmable Transmitter. PR Electronics 6333B intrinsically safe 2-wire programmable temperature transmitter offers unrivalled performance in applications making heavy demands on accuracy to convert a wide array of input types to a 4 ??20 mA output signal. The 6333 transmitters provides unrivalled input versatility with galvanic isolation up to 1.5 kVAC for 2 ; 3 Wire RTD and linear resistance signals. Input sensor redundancy function maintains process availability and safety in the event of primary sensor failure The 6300 series transmitters are quickly and easily programmable to the specific application. Configuration via a standard PC and user-friendly software, PReset, available as a free download. Parameters for input, output, sensor error detection and process calibration can be configured via PReset within a few minutes. Features and Benefits. DIN Rail mounting Galvanic isolation Can be installed in Ex zone 0 Sensor drift detection maintains measuring point reliability Flexible input capability, with choice of output modes Superior accuracy ensures true, reliable measurements Fast response time easily supports safety and cost-critical applications High immunity to conducted noise: tested against 10 Vrms in the range 15 Hz??00 MHz Continuous check of vital stored data for safety reasons Runtime meters provide a valuable history of the process temperature and the ambient temperature around the transmitter Very low temperature coefficient ensuring maximum accuracy across changing ambient conditions

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지