MPN : TES-1800-G

RS PRO Loop Impendance Tester, Loop Impedance Test Type 3 Wire
  • 브랜드

    RS PRO

  • 무원상품코드

    M010517008983

  • 타입별
  • 주문가능수량

    품 절

  • 최소주문수량0
  • 판매단위0
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택

총금액
(VAT 별도)

  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 RS PRO
제조사품명 TES-1800-G
간략설명 RS PRO Loop Impendance Tester, Loop Impedance Test Type 3 Wire

■ 제품사양

Loop Impedance Test
타입 = 3 Wire PSC Display = Yes Best Loop Test Accuracy = ±2% Display
타입 = LCD Power Source = Mains
무게 = 800g Plug
타입 =
타입 G - British 3-pin When conducting a test, particularly on earth spikes, do not touch any exposed metal work. If the overheat symbol appears in the display disconnect the device from the mains and allow to cool down. EN61557 and BS7671 wiring regulations, EN61010-1 300V CAT III. Test Lead with IEC connector (AC cord), external earth probe, neck strap, user manual. RS PRO IPT 1800 Digital PSC and Loop Tester. RS PRO IPT 1800 is a great value, microprocessor-controlled PSC/loop tester. Its high loop impedance range permits direct measurement of ground spikes. Features include an auto lock-out if the test resister overheats. Features and Benefits:. ;ul> ;li>Large 3 digit 2000 count with analog bargraph LCD ;/li> ;li>Microprocessor controlled for highest accuracy and reliability ;/li> ;li>High impedance ranges allow direct measurements of ground spikes ;/li> ;li>Automatic lock heat ??added safety if test resistor overheats ;/li> ;li>200 A, 2000 A ; 20 kA PSC ranges ;/li> ;li>20 Ω, 200 Ω ; 2000 Ω loop impedance ranges ;/li> ;li>AC voltage indication ;/li> ;li>Direct reading of Prospective Short Circuit Current (PSC) ;/li> ;li>Over temperature test inhibit with indication ;/li> ;li>
크기 180 x 130 x 70 mm ;/li> ;li>
무게 800 g approximately ;/li> ;/ul>. Typical Applications:. Earth loop impedance testers are used by contractors for testing electrical installations in industrial and commercial applications. FAQs. What is earth loop impedance testing? This is also known as loop testing. Earth loop impedance testing is carries out to make sure that if an error occurs in an electrical installation, there is enough current to flow in order to operate the fuse or circuit breaker protecting the faulty circuit within a predetermined time. The purpose is to make sure that the circuit is disconnected quickly in order to prevent overheating and possibly a fire. What are PSC tests? Prospective Short Circuit (PSC) tests are designed to calculate the maximum current that will flow within a fault loop path during the event of an electrical fault.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지