상품이미지
  •  상품이미지

MPN : 232009

IDEM ESL Series Emergency Stop Push Button, 2NC + 2NO, Surface Mount, IP67, IP69K
  • 브랜드

    IDEM

  • 무원상품코드

    M012234010115

  • 타입별
    EA
  • 주문가능수량

    14

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 180,218원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 IDEM
제조사품명 232009
간략설명 IDEM ESL Series Emergency Stop Push Button, 2NC + 2NO, Surface Mount, IP67, IP69K

■ 제품사양


장착형태 = Surface Mount Contact Configuration = 2NC + 2NO Push Button Actuation = Twist Release Illuminated = No
시리즈 = ESL IP Rating = IP67, IP69K Push Button Shape = Round Voltage Rating = 240V ac/dc Supply Current = 3A Depth = 105mm Width = 94mm
높이 = 66mm EN 60947-5-1, EN 60947-5-5, EN 62061, UL 508, ISO 13850, ISO 13849-1. IDEM Emergency Stop Switches. The ESL-SS series of Pushbuttons from IDEM are standard duty emergency stop switches designed to provide robust emergency stop protection for machines or exposed conveyors. These round Emergency Stop Push buttons with red plastic heads are designed to be used by operators to shut down a machine, system or process. In combination with any dual channel safety monitoring controllers these switches can be used as an emergency stop devices and monitored for up to Category 4/PLe to ISO13849-1. The mounting of Emergency Stop Switches on machines and sections of plant conveyors that cannot by protected by the operators are ideal for ESL-SS series to be used. All IDEM ??s ESL-SS series conform to European Standard EN ISO13850 (formerly EN418) and IEC60947-5-5. They have a positive mechanical linkage between the switch contacts and the E Stop Button. The switches are mechanically latched and can then only be returned to the operational condition by pressing the reset button as required by EN ISO13850. The range of Explosion Push Button Switches can withstand sparking and flames and are IECEx and ATEX certified. These certificates describe the requirements for equipment intended for use in (potentially) hazardous areas. ATEX and IECEx both have a quality assurance system. Besides the product certification, in both cases a quality system must be set up by the manufacturer and will periodically be checked by a Notified Body. For both, the quality system is mainly based on ISO 9001 with additional requirements for the design, manufacture and testing of explosion proof products. Stock nos. ; 826-4413 826-4413 , ; 826-4417 826-4417 , ; 826-4426 826-4426 ; ; 826-4429 826-4429 have button protection shroud with padlock holes for Lock Off" in maintenance situations Stock nos. ; 826-4426 826-4426 ; ; 826-4429 826-4429 have 2-colour LED (Steady Green/Flashing Red)

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지