상품이미지
  •  상품이미지

MPN : Z2-K-1.0-7/0.2-MP-ANSI

RS PRO Type K Thermocouple 7/0.2mm Diameter ??+250°C
  • 브랜드

    RS PRO

  • 무원상품코드

    M012169008653

  • 타입별
    EA
  • 주문가능수량

    품 절

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 13,449원

  • 수량단가2 : 10개 ~ 12,913원

  • 수량단가3 : 50개 ~ 10,627원


총금액
(VAT 별도)

  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 RS PRO
제조사품명 Z2-K-1.0-7/0.2-MP-ANSI
간략설명 RS PRO Type K Thermocouple 7/0.2mm Diameter ??+250°C

■ 제품사양

Thermocouple
타입 = K Probe Diameter = 7/0.2mm Probe Material = Nickel Aluminium, Nickel Chrome Termination
타입 = Miniature Plug Cable Length = 1m Standards Met = ANSI Class 1 cable specification in accordance with BS EN 60584-3:2008 ANSI MC96.1 class 1. RS Pro PFA
타입 K and T Exposed Welded Tip Thermocouples. From RS Pro a range of type T and K bare wire thermocouple temperature sensors with a tolerance to ANSI MC96.1 class 1 for optimum accuracy. These thermocouple temperature sensors have a durable construction a welded exposed junction for a fast response time. One end of the thermocouple is terminated with a miniature plug for a quick and easy connection. The twin twisted leads of these thermocouple sensors are insulated with durable Teflon PFA. How does a Thermocouple Work?. A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect. What is a Welded Exposed Junction?. A welded exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures. Key Features and Benefits. Welded, exposed junction for fast response times Durable construction with PFA insulation for resistance to oils, acid, fluids and good mechanical strength and flexibility Tolerance to ANSI MC96.1 Class 1 for optimum accuracy Miniature plug termination for quick and easy connection Temperature range of -75 to +250°C. Applications. These grounded junction
타입 K and T bare wire thermocouples are ideal for test and development applications including test and measurement, temperature mapping and OEM applications

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-10-31
2
답변 완료
2024-10-24
3
신청 접수
2024-10-21
4
신청 접수
2024-05-27
6
답변 완료
2024-05-13
7
답변 완료
2024-04-16
8
답변 완료
2023-12-08
9
답변 완료
2023-11-21
상품정보이미지