상품이미지
  •  상품이미지

MPN : 3117

PR Electronics 3100 Series Bipolar Isolated Converter, 16.8 ??31.2V dc, Current, Voltage Input, Current, Voltage
  • 브랜드

    PR Electronics

  • 무원상품코드

    M012152000586

  • 타입별
    EA
  • 주문가능수량

    7

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 294,466원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 PR Electronics
제조사품명 3117
간략설명 PR Electronics 3100 Series Bipolar Isolated Converter, 16.8 ??31.2V dc, Current, Voltage Input, Current, Voltage

■ 제품사양

Module
타입 = Bipolar Isolated Converter Input Signal
타입 = Current, Voltage Output Signal
타입 = Current, Voltage Supply Voltage = 16.8 ??31.2V dc Input Range = -11.5 ??11.5 V, -23 ??23mA Output Range = 0 ??11.5 V, 0 ??23mA Hazardous Area Certification = ATEX
장착형태 = DIN Rail Mount Operating Temperature Range = -25 ??+70°C
최소 작동 온도 = -25°C 3100
타입 - Bipolar Isolated Converter. 3117 and 3118 types are for isolation and conversion of standard current and voltage signals. Suitable for galvanic separation of analog current and voltage signals and elimination of ground loops and measurement of floating signals. Features and Benefits. Converter for current and voltage bipolar process signals to unipolar signals Response time ; 7 ms Splitter function: 1 in - 2 out (only 3118 type, stock-no. ; 796-7092 796-7092 ) Multiple signal ranges are selectable via DIP-switches Excellent accuracy, better than 0.05 % of selected range All terminals are protected against overvoltage and polarity error High galvanic isolation of 2.5 kVAC. DIP-switch programming. Re-calibration is not needed after changing the DIP-switch range settings. Just change the DIP-switch, cycle the power to the unit and obtain the new, pre-calibrated I/O range. HART programming is enabled for selected devices. Mounting. Devices can be mounted both vertically and horizontally with no air gap separation required. The devices snap onto a power rail or DIN rail and are easily detached by lifting the bottom lock. High level of isolation. Safe galvanic isolation of 2.5 kVAC provides high noise immunity and prevents ground loops for accurate delivery of the process signal to your control system. Device status indicators. A front LED indicates device status, e.g. an error in the set-up, sensor or hardware. Over voltage- / polarity protection. All terminals can withstand up to ±31.2 VDC and are protected against incorrect supply wiring to ensure safe, error-free installation.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지