상품이미지
  •  상품이미지

MPN : 0560 1040

Testo 104-IR Infrared Thermometer, -30°C Min, +250°C Max, °C Measurements
  • 브랜드

    Testo

  • 무원상품코드

    M012130007078

  • 타입별
    EA
  • 주문가능수량

    25

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 206,715원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Testo
제조사품명 0560 1040
간략설명 Testo 104-IR Infrared Thermometer, -30°C Min, ±1.5 %, ±1 °C, ±2.0 °C, ±2.5 °C Accuracy, °C Measurements
문서자료 https://documents.rs-online.com/techlib:/itc_doclist_GB.htm?stockno=7770453

■ 제품사양

Absolute Maximum Temperature Measurement = +250°C Temperature Scale = Centigrade Absolute Minimum Temperature Measurement = -30°C Model Number p = 104-IR Resolution = 0.1 °C Length = 281mm Width = 48mm
높이 = 21mm
크기 = 281 x 48 x 21mm
무게 = 197g 2 batteries type AAA and calibration protocol. Testo 104-IR Multi-Scanning Thermometer with Penetration Control. Infrared and penetration measurements are made possible with this multipurpose laser thermometer. Featuring a precise 2-point laser and 10:1 optics display for error-free measurements. This device is high quality, robust and fits inside your pocket thanks to it's folding mechanism. Waterproof (IP65) and HACCP-compliant, the contact or non-contact option makes this the ideal thermometer for the food industry. Just pull out the probe and the display jumps in to action, whilst the IR measurements start at the touch of a button. The 104-IR can scan the surface temperature of individual foods or entire pallets, making quality control quick and simple. Features and Benefits:. Easy to use -30°C to 250°C measurement range LCD display illuminated 197g 0.10 to 1.00 adjustable emissivity. FAQ's. Are infrared thermometers dangerous?. Infrared thermometers are not harmful, they do not emit radiation, only measure it like a digital camera. How accurate are infrared thermometers?. The majority of IR thermometers have a measurement error specification, which shows their best accuracy. The surface being measured can also affect accuracy. Reflective objects result in lower measurements than the actual temperature, whilst non-reflective surfaces give higher measurement. The emissivity of a surface is how effective it is at emitting energy as thermal radiation, as such some IR thermometers have adjustable emissivity settings. Distance to spot ratio is also essential in providing accurate temperature measurements, if an infrared thermometer is too close to its target area, heat can build up in the device. This can give false readings or damage the temperature sensors, therefore it is essential to always follow a manufacturers guidelines.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-05-27
3
답변 완료
2024-05-13
4
답변 완료
2024-04-16
5
답변 완료
2023-12-08
6
답변 완료
2023-11-21
상품정보이미지