MPN : FLUKE 62 MAX

Fluke 62 MAX Infrared Thermometer, -30°C Min, +500°C Max, °C and °F Measurements
  • 브랜드

    Fluke

  • 무원상품코드

    M012113000785

  • 타입별
    EA
  • 주문가능수량

    306

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 177,910원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Fluke
제조사품명 FLUKE 62 MAX
간략설명 Fluke 62 MAX Infrared Thermometer, -30°C Min, +500°C Max, °C and °F Measurements

■ 제품사양

Absolute Maximum Temperature Measurement = +500°C Temperature Scale = Centigrade, Fahrenheit Absolute Minimum Temperature Measurement = -30°C Emissivity = 0.1 ??1 Model Number p = 62 MAX Resolution = 0.1 °C Response Time = 500 ms Length = 175mm Width = 85mm
높이 = 75mm
무게 = 255g EN/IEC 61010-1: 2001. FDA and EN 60825-1 Class II. Fluke 62 MAX and MAX+ Infrared Thermometers. Fluke 62 MAX and 62 MAX+ infrared thermometers are small, exceptionally accurate and easy-to-use. The instruments are IP54 rated for dust and water resistance. They are precise yet rugged enough to resist a 3 m drop. Features ; Benefits. IP54 rated for dust and water resistance. 3 m (9.8 ft) drop tested. Ergonomically designed for a natural hand fit. Small and lightweight. Clips to tool belt or belt loop, or easily fits into tool box. Precise laser technology makes for accurate and repeatable measurements. The 62 MAX+ has dual rotating lasers to help identify area to be measured (the measurement area is the spot between the dots). Large backlit display makes data easier to read, even in dark areas. Displays the minimum, maximum or average temperature - or the difference between two measurements. Alarm: Hi and Lo alarms for rapid display of measurements outside the limits. 62 MAX and 62 MAX+ powered by single, standard AA battery. How accurate are infrared thermometers?. The majority of IR thermometers have a measurement error specification, which shows their best accuracy. The surface being measured can also affect accuracy. Reflective objects result in lower measurements than the actual temperature, whilst non-reflective surfaces give higher measurement. The emissivity of a surface is how effective it is at emitting energy as thermal radiation, as such some IR thermometers have adjustable emissivity settings. Distance to spot ratio is also essential in providing accurate temperature measurements, if an infrared thermometer is too close to its target area, heat can build up in the device. This can give false readings or damage the sensors, therefore it is essential to always follow a manufacturers guidelines.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지