상품이미지
  •  상품이미지

MPN : HPL500

Unipower 40 A Motor Load Monitor, 100 ??400 V ac
  • 브랜드

    Unipower

  • 무원상품코드

    M012100000793

  • 타입별
    EA
  • 주문가능수량

    1

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 980,210원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Unipower
제조사품명 HPL500
간략설명 Unipower 40 A Motor Load Monitor, 100 ??400 V ac

■ 제품사양


Current 등급 = 40 A Motor Protection Component = Load Monitor Supply Voltage = 100 ??400 V ac
시리즈 = HPL Output = 3 Enclosure
타입 = Din Rail, Wall Mount CE, UL and GOST-R. HPL500 Digital Motor Load Monitor. The HPL500 replaces the HPL420 and also incorporates many new features, however it has been designed so that users of the HPL420 will be familiar with its set-up procedure. The display is used as a reference enabling true motor load, trip levels and all other variables to be displayed and programmed quickly and accurately using only three push buttons. For two speed motor applications an input allows the application to select the active limit The HPL500 is usually mounted in the motor control panel and is connected to a convenient point on the motor supply (before Inverter - if used). Therefore no external field wiring or sensors in the equipment are necessary. In addition to displaying true motor power in real time the units capture and, on demand, display the instantaneous minimum and maximum power levels to assist in setting up trip limits and fault diagnosis. The HPL500 features a current feed-through tube for measuring continuous motor currents up to 40 amps, (27.7kW at 3 x 400vac). Therefore no Current Transformer is required unless the motors continuous current exceeds 40A. A specially designed power supply (Patent Pending) allows the motor voltage to be programmable from 100 ??400vac single phase and 100 ??575vac 3-phase making the HPL500 suitable for world-wide use. The 0(4)-20ma analogue output, which is proportional to motor load, can be scaled to the range of measured power and can be inverted for use in closed loop control systems. Measures true motor load in kW (?? x I x V x Cos?) and futures a digital display of kW% and kW, and programmable trips for over and/or under load events Can be programmed to calculate Shaft Output Power P2 if required Protects equipment from damage caused by the motor running against a jam, blockage or under load Used in processes to trigger actions when predetermined load levels are reached (end point monitoring) Three digital delay timers, programmable from 0.1-99.9 seconds are incorporated to time out motor start surge and short duration over and under power events which could cause nuisance tripping Two output relays are individually programmable, over or under-load alarms Output relay state (NO or NC) can also be programmed All settings are key-lock protected Used for the over/under load protection of: Pumps (dry run, closed valve), Fans (broken belt, closed damper), Conveyors (screw and belt) Separation screens, Macerators, Scrapers, Mechanical drives (gearboxes, chains) Also suitable for Process Control, PLC and SCADA input

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-05-27
3
답변 완료
2024-05-13
4
답변 완료
2024-04-16
5
답변 완료
2023-12-08
6
답변 완료
2023-11-21
상품정보이미지