Fluke 53 II Wired Digital Thermometer for Industrial Use, E, J, K, N, R, S, T Probe, 1 Input(s), +1767°C Max, ±0.05 %
  • 브랜드

    Fluke

  • 무원상품코드

    M012036003462

  • 타입별
    EA
  • 주문가능수량

    7

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 597,435원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Fluke
제조사품명 3621096
간략설명 Fluke 53 II Wired Digital Thermometer for Industrial Use, E, J, K, N, R, S, T Probe, 1 Input(s), +1767°C Max, ±0.05 %

■ 제품사양

Absolute Maximum Temperature Measurement = +1767°C Thermometer
타입 = Wired Best Accuracy = ±0.05 % Number of Temperature Inputs = 1 Resolution = 0.1 °C Data Storage = Yes Length = 173mm Width = 86mm
높이 = 38mm Temperature Scale = Centigrade, Fahrenheit Model Number = 53 II Instruction leaflet, holster, battery (fitted) 1 off type K thermocouple (Model 51-II ; model 53-2-B) 2 off type K thermocouple (Model 52-II ; Model 54-2-B). Fluke 53-2B ; 54-2B need the Fluke FVF- SC2 FlukeView software and USB lead RS ; 385-0599 385-0599. Fluke 50
시리즈 II Thermometer. The Fluke 50
시리즈 II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged, handheld test tool. Fluke 51 II and 52 II Features. Model 51 II single input, Model 52 II dual input Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX or AVG Relative time clock on MIN, MAX and AVG provides a time reference for major events Electronic offset function allows compensation of thermocouple errors to maximise overall accuracy Measures J, K, T and E type thermocouples Readout in °C, °F or Kelvin (K) User-friendly front panel is easy to set up and operate Sleep mode increases battery life. Fluke 53 II B and 54 II B Extra Features. Model 51-II single input: Model 52-II dual input. Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX or AVG. Relative time clock on MIN, MAX and AVG provides a time reference for major events. Electronic offset function allows compensation of thermocouple errors to maximise overall accuracy. Measures J, K, T and E type thermocouples. Readout in °C, °F or Kelvin (K). User friendly front panel is easy to set up and operate. Sleep mode increases battery life. Battery door allows easy battery replacement without breaking the calibration seal. Splash and dust resistant case protected by impact absorbing holster. Model 53 II B single input, Model 54 II B dual input Data logging up to 500 points of data with user-adjustable recording interval Extra thermocouple types N, R, S Real-time clock captures the exact time of day when events occur Recall function allows logged data to be easily reviewed on the meter display Contents of thermometer memory can be transferred to PC using FlukeView Forms, available separately Fluke 53-2B ; 54-2B Compatible with the Fluke FVF- SC2 FlukeView software and USB lead RS 385-0599 IR communication port allows data to be exported to optional FlukeView??Temperature PC software for further analysis and graphing. Fluke 53-2-B and 54-2B additional features:. Model 53-2-B single input: Model 54-2-B dual input. Data logging up to 500 points of data with user adjustable recording interval. Additional thermocouple types N, R, and S. Real time clock captures the exact time of day when events occur. Recall function allows logged data to be easily reviewed on the meter display. You can transfer the contents of the thermometer ??s memory to a PC using FlukeView Forms. Fluke 53-2B ; 54-2B Compatible with the Fluke FVF- SC2 FlukeView software and USB lead RS ; 385-0599 385-0599. IR communication port allows data to be exported to optional FlukeView??Temperature PC software for further analysis and graphing

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지