■ 제품사양
Absolute Maximum DC Current Measurement = 100mA dc Absolute Maximum DC Voltage Measurement = 30V dc Model Number = 773 DC Current Measurement Resolution = 10uA Best DC Current Accuracy = ±1% + 5 Digits Clamp Meter
타입 = DC Current Clamp Meter Best DC Voltage Accuracy = 0.2% + 2 Digits Power Source = Battery Fluke Clamp MeterThe Fluke milliamp process clamp meter measures current up to 99.9mA DC and voltage up to 30V DC. It saves time and money by measuring 4mA to 20mA signals five times faster than with traditional DMMs, and without breaking the loop. It can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces. Note: For details of the 771 process clamp meter see stock no. 287-642 Supplied with: 4 AA alkaline batteries, test lead set with integral prods and 2 crocodile clips test leads with integral grabber clips soft carry case & instructionsFeatures and BenefitsSources 4mA to 20mA signals for testing control system I/O or I/Ps Measures 4mA to 20mA signals with in-circuit measurement Simultaneously measures mA in-circuit with 24V loop power for powering and testing transmitters Source output signals in a linear ramp or 25% step output- Automatically change the 4mA to 20 mA output for remote testing Power-saving features, auto-off, backlight timeout extend battery life DC voltage measurement to verify 24V power supplies or voltage I/O signals Source DC voltage to test input devices that accept a 1V to 5V or 0V to 10V signal The scaled output provides a continuous mA signal that corresponds to the 4mA to 20mA signal measured by the mA clamp- Output mA signal enables a logging DMM or other device to record the 4mA to 20mA signal without breaking the loop mA in/out: simultaneously measure the mA signal with the clamp and source an mA signal - apply an mA input signal to a device and measure its 4mA to 20mA output on devices such as valves or mA isolators Voltage output linear ramp or 25% step output- Automatically change the voltage output for remote testing Delivers 0.01mA resolution and sensitivity Measurement Spotlight to illuminate hard to see wires in dark enclosure Operating temperature ranges between -10°C and 50°CApplicationsTroubleshooting transmitters Troubleshooting valves Troubleshooting programmable logic controllers (PLCs) found in process plantsCertificationsEN61010-1 IP40 rated