MPN : MTL7760AC/RS

Eaton 2 Channel Zener Barrier, Switch/Proximity Detector Interface, RTD, Thermocouple Input, ATEX
  • 브랜드

    Eaton

  • 무원상품코드

    M011901004270

  • 타입별
    EA
  • 주문가능수량

    28

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 338,227원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Eaton
제조사품명 MTL7760AC/RS
간략설명 Eaton 2 Channel Zener Barrier, Switch/Proximity Detector Interface, RTD, Thermocouple Input, ATEX

■ 제품사양

Barrier
타입 = Zener Barrier Number of Channels = 2 Supply Voltage = 10V dc Module
타입 = Switch/Proximity Detector Interface Input Signal
타입 = RTD, Thermocouple Maximum Current = 200mA
최소 작동 온도 = -20°C
최대 작동 온도 = +65°C Maximum Voltage = 6.7V dc Safety Current Maximum = 200mA Safety Current Resistance = 50Ω Safety Voltage Maximum = 6.7 V dc Hazardous Area Certification = ATEX
시리즈 = MTL7700 BAS01 ATEX 7217. II 1 GD EEx ia IIC T6. Power bus facility applicable to MTL7706+, 7741 and 7787+ barriers. 7700
시리즈 Safety Barrier. The MTL7700
시리즈 of intrinsically safe passive network devices use zener diodes, resistors and fuses to safely divert excess electrical energy to ground and prevent sparking or overheating of equipment in hazardous areas. The MTL7700 intrinsic safety device provides quick and easy installation and maintenance with removable terminals, the loop can be disconnect by simply unplugging the terminals from the side of the module. Wire entry is also angled to assist wiring within limited space enclosures. DIN-rail mountable the MTL7700 intrinsic safety devices clamp simply and securely onto standard T-section DIN rail, simultaneously making a reliable intrinsically safe earth connection. For applications where field device power is required for switch inputs or 2-wire transmitters, the MTL7700 barrier range provides a bussed power feed facility. When used in conjunction with the MTL7798 power feed module the user has a fully protected, electronically fused supply to many barriers with no additional wiring required. All MTL7700 range zener barriers are based on the same simple principle. Each channel contains two stages of pulse-tested Zener or forward-connected diodes and an ??infallible ??terminating resistor. In the event of an electrical fault in the safe area, the diodes limit the voltage that can reach the hazardous area and the resistor limits the current. A fuse protects the diodes, and the two stages of voltage limitation ensure continued safety if either stage should fail. No active output current limiting circuits are employed. All models are certified ??ia ??for all zones and ??IIC ??for all explosive atmospheres (except MTL7707P+ and MTL7729P+, 'ia' 'IIB'). Features and Benefits. Standard DIN rail mount Removable, colour-coded terminals Bussed power feed to other modules Relay and solid state switch modules Dual channel variants - 6.3mm per channel Proximity detector inputs Direct replacement for MTL700
시리즈 Compatible terminal numbering and safety descriptions
크기: 105 x 90 x 12.6mm

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지