MPN : 278286 SDAINLM12(230V50HZ,240V

Eaton 5.5 kW Contactor
  • 브랜드

    Eaton

  • 무원상품코드

    M011888004176

  • 타입별
    EA
  • 주문가능수량

    4

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 536,771원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Eaton
제조사품명 278286 SDAINLM12(230V50HZ,240V
간략설명 Eaton 5.5 kW Contactor

■ 제품사양

Power Rating = 5.5 kW Number of Poles = 3
시리즈 = SDAINL FLC figures quoted are maximum. The overload specified has been determined by applying the following formula: 0.58 x motor FLC.,Allow additional clearance dimensions for the wiring bar above and below the starter.,Thermal overload ZB12-16 is not currently stocked. The starters which use the X Start range of components are not compatible with DILM components. Star Delta - Open Chassis. Open chassis Star Delta starter for use within customised enclosures, enabling quick and easy installation and direct mounting onto 35mm DIN rail.,Manufactured using readily available Moeller components which conform to the latest IEC 947 standards and pre-wired to accept the Moeller Z00 or ZB thermal overloads which offer single phasing sensitivity to IEC 947-4.,Star Delta Open Chassis starters comprise of a Main, Delta and Star contactors, Star Delta timer (adjustable between 0 and 30 seconds) and circuit diagram. Features ; Benefits:. Overload relay is not supplied and must be ordered separately Manufacturer part numbers beginning with SDAINL 00AM , 0M , 0AM, 1M , M12 , M16 , M22 use ZB12 overloads (typical example stock no. ; 493-1239 493-1239 ) Manufacturer part numbers beginning with SDAINL M30 , M45 and M55 use ZB32 overloads (typical example stock no. ; 493-1245 493-1245 ) Terminal protection to IP20 Operating temperature range -25 to +40°C 7.5kW (SDAINL00AM) = H77 x W162 x D112mm 12.5kW ; 18.5kW (SDAINL0M ; SDAINL0AM) = H91 x W162 x D117mm 22kW (SDAINL1M) = H98 x W188 x D135mm 5.5 to 11kW (SDAINLM12 to SDAINLM22) = H68 x W158 x D125.2mm 15, 22 ; 30kW (SDAINLM30 to SDAINLM55) = H85 x W158 x D147.3mm. Note: FLC figures quoted are maximum. The overload specified has been determined by applying the following formula: 0.58 x motor FLC. Allow additional clearance dimensions for the wiring bar above and below the starter. How Does a Star Delta Starter Work?. A star delta starter is a reduced voltage motor starter and is designed to control a three-phase induction motor by reducing the starting current. Typically having a third of the inrush current compared to a DOL starter. The windings in this starter are switched between a star connection during the starting period and a delta connection once the motor reaches the required speed. A star delta power circuit will have a contactor configuration within the relay of triple pole (star) and double-throw (delta).

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-05-27
3
답변 완료
2024-05-13
4
답변 완료
2024-04-16
5
답변 완료
2023-12-08
6
답변 완료
2023-11-21
상품정보이미지