상품이미지
  •  상품이미지

MPN : 5SY6110-6

Siemens Sentron 5SY6 MCB, 1P Poles, 10A Curve B, 230V AC, 6 kA Breaking Capacity, MCB
  • 브랜드

    Siemens

  • 무원상품코드

    M011865010801

  • 타입별
    EA
  • 주문가능수량

    29

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 22,065원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Siemens
제조사품명 5SY6110-6
간략설명 Siemens Sentron 5SY6 MCB, 1P Poles, 10A Curve B, 230V AC, 6 kA Breaking Capacity, MCB

■ 제품사양

Number of Poles = 1P
Current 등급 = 10A Tripping Characteristics =
타입 B Rated AC Voltage = 230 V, 400V Range = Sentron Breaking Capacity at Maximum Voltage Rating = 6 kA Circuit Breaker
타입 = MCB Mounting Style = DIN Rail Mount Width = 17.5mm Length = 89.8mm Depth = 76mm EN 60898, VDE 0641 part of 11, IEC 60898. Sentron 5SY
시리즈 Miniature circuit breakers. Miniature circuit breakers from Siemens, offer the highest quality and reliability. The excellent technical properties of the devices mean you are always on the safe side. Apart from that you benefit from the innovative mounting options which enable quick and easy installation. The miniature circuit breakers from Siemens can be combined as required with a wide range of supplementary components e.g. control current switches, fault signal contacts, shunt releases, under voltage releases, remote operating mechanisms or with RCCB units to provide protection for persons and against fire. Features and Benefits. Enclosure: IP20 equipment Automatic cut-out, 1, 2, 3 and 4-pole DIN rail assembly For use in industry, and in the functional and residential construction sector Supports fast and convenient removal from the assembly. Standards. IEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar Installations. In the UK traditionally known as miniature circuit breakers (MCB ??s). Q: What is the differences in the Tripping Curves B, C, and D?. A: Curve B: Tripping: 3 to 5 times the rated current. Applications: protection of generators, persons, very long cables Curve C: Tripping: 5 to 10 times the rated current Applications: protection of circuits and general applications Curve D: Tripping: 10 to 14 times the rated current Applications: protection of high surge circuits, welders, transformers and motors

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지