상품이미지
  •  상품이미지

MPN : XQ-213-RS

RS PRO Type K Thermocouple 1m Length, ??+260°C
  • 브랜드

    RS PRO

  • 무원상품코드

    M011747008496

  • 타입별
    EA
  • 주문가능수량

    948

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 34,054원

  • 수량단가2 : 6개 ~ 32,850원

  • 수량단가3 : 30개 ~ 27,037원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 RS PRO
제조사품명 XQ-213-RS
간략설명 RS PRO Type K Exposed Junction Thermocouple 1m Length, 0.076mm Diameter → +260°C
문서자료 https://documents.rs-online.com/techlib:/itc_doclist_GB.htm?stockno=3971589

■ 제품사양

Thermocouple
타입 = K Probe Length = 1m Maximum Temperature Sensed = +260°C Termination
타입 = Cable Cable Length = 1m Standards Met = ANSI RS Pro ANSI
타입 K Fine Gauge Exposed Welded Tip Thermocouples. From RS Pro a range of type K fine gauge wire thermocouple temperature sensors conforming to ANSI standards. These thermocouple temperature sensors feature a welded tip exposed junction for a fast response time. The lead consists of 0.0076 mm conductors with durable Teflon PFA insulation colour coded to ANSI specifications. How does a Thermocouple Work?. A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect. What is a Welded Exposed Junction?. An exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures. Features and Benefits. Welded, exposed junction for fast response times Durable PFA insulated leads for resistance to oils, acid, fluids and good mechanical strength and flexibility Conforms to ANSI standards Temperature range of -75 to +260°C. Applications. These
타입 K fine wire gauge thermocouples are ideal for test and development applications including test and measurement, temperature mapping and OEM applications

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-05-27
3
답변 완료
2024-05-13
4
답변 완료
2024-04-16
5
답변 완료
2023-12-08
6
답변 완료
2023-11-21
상품정보이미지