상품이미지
  •  상품이미지

MPN : LC1K1210B7

Schneider Electric TeSys K LC1K Contactor, 24 V ac Coil, 3 Pole, 12 A, 5.5 kW, 3NO
  • 브랜드

    Schneider Electric

  • 무원상품코드

    M011730003160

  • 타입별
    EA
  • 주문가능수량

    41

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 49,038원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Schneider Electric
제조사품명 LC1K1210B7
간략설명 Schneider Electric TeSys K LC1K Contactor, 24 V ac Coil, 3 Pole, 12 A, 5.5 kW, 3NO

■ 제품사양

Coil Voltage = 24 V ac Number of Poles = 3 Contact
Current 등급 = 12 A Power Rating = 5.5 kW Normal State Configuration = 3NO Contact Voltage Rating = 690 V ac Range = TeSys K Number Of Auxiliary Contacts = 1 Terminal
타입 = Screw Width = 45mm Depth = 57mm Better World Product = Yes
최대 작동 온도 = +50°C Schneider Electric LC1K TeSys K Miniature Contactors. TeSys K Miniature Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and for inductive motor applications. The TeSys K contactors offer quick simple setup while maintaining compliance with international standards. A special armature structure design allows all devices in the range, either AC or DC, to have the same physical size and panel footprint for convenience. Features and Benefits. Built-in auxiliary contacts for added switching capability Screw connections: IP20 finger-safe terminals with both North American and International terminal markings Can be panel mounted with screws or DIN Rail mounted Easily installed accessories Instantaneous auxiliary contact Flexible control circuit to suit a wide range of applications High-fault short circuit current ratings provide the flexibility to select any component. What does the utilisation category AC1 and AC3 mean for the TeSys contactors?. Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions. AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution. AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units. Are the TeSys K contactors suitable for applications in AC4 usage?. The LC1K series is suitable up to a maximum of 440 V ac in category AC4. Is the TeSys K range a double break pole type contactor?. Yes the TeSys K range uses linear translation movement that provides double breaking of the poles.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지