상품이미지
  •  상품이미지
  •  상품이미지

MPN : BA9026 3AC50/60Hz 200-460V 3kW

Dold 3 kW Soft Starter, 460 V ac, 3 Phase, IP20, IP40
  • 브랜드

    Dold

  • 무원상품코드

    M011535007768

  • 타입별
    EA
  • 주문가능수량

    품 절

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 762,032원


총금액
(VAT 별도)

  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 Dold
제조사품명 BA9026 3AC50/60Hz 200-460V 3kW
간략설명 Dold 3 kW Soft Starter, 460 V ac, 3 Phase, IP20, IP40

■ 제품사양

Power Rating = 3 kW Motor Starter
타입 = Soft Start Voltage Rating = 460 V Phase = 3
Current 등급 = 8 A IP Rating = IP20, IP40
전체 길이 = 121mm Overall Width = 45mm Overall Depth = 74mm
시리즈 = BA9026 The BA9026 must not be operated with a capacitive load (e.g. reactive power compensation) at the output. In the decoupled state (without load), the starting behaviour is not particularly smooth. Soft starter, BA9026. All three motor phases are influenced by the BA9026 by means of phase control using thyristors in such a way that the currents can rise steadily. The motor torque behaves in exactly the same way during start-up. This guarantees that the drive can start up without jerking. It is thus impossible for drive elements to be damaged, because the abrupt starting torque caused by direct starting is not generated. This property enables a cost-efficient design for the drive elements. After starting, the power electronics are bridged via internal relay contacts to minimise losses in the device. The smooth deceleration function also prolongs the natural deceleration time of the drive unit to prevent abrupt stopping. Applications. Machines with gear, belt and chain drives Conveyor belts, fans, pumps, compressors Woodworking machines, centrifuges Packaging machines, door operating mechanisms Inrush current limitation for three-phase transformers. Features. With smooth deceleration function Increases the service life of asynchronous motors and mechanical drive components for motor ratings up to 3 kW With 3-phase motor control Starting time, deceleration time and starting and deceleration torque can be adjusted separately Power semiconductors bridged after successful start-up Large input voltage range for the power semiconductors Galvanically isolated DC control input Galvanically isolated DC auxiliary voltage With integrated temperature monitoring Overall width 45 mm

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지