■ 제품필수정보
제조사 |
RS PRO |
제조사품명 |
XQ-1787-RS |
간략설명 |
RS PRO Type J Thermocouple 3m Length, 1/0.2mm Diameter, -75°C ??+260°C |
■ 제품사양
Thermocouple
타입 = J Probe Diameter = 1/0.2mm Probe Length = 3m Probe Material = Teflon PTFE Termination
타입 = Twin Twisted Tail Cable Length = 3m Standards Met = IEC 584-3 Minimum Temperature Sensed = -75°C RS PRO IEC
타입 J, K &
타입 T Exposed Welded Tip Thermocouple and Miniature Plug Introducing the range of RS PRO
타입 J, K and
타입 T fine wire temperature sensing thermocouples that conform to IEC-584-3 standards with a Class 1 tolerance for optimum performance. These
타입 K and
타입 T fine wire temperature sensors have a durable Teflon PTFE insulated class 1 twin-twisted 1/0.2 mm lead. The lead is terminated with a rewireable miniature flat pin plug for a quick and easy connection. These thermocouples have an exposed welded junction which enables them to operate with a fast response time. Features and Benefits: IEC-584-3 class 1 tolerance for optimum accuracy Miniature plug for quick and easy connection Exposed welded junction for fast response Durable Teflon PTFE insulation for resistance to oils, acids and fluids and good mechanical strength and flexibility Temperature range from -75 to +250°C Applications: These
타입 J, K and
타입 T fine wire thermocouple temperature sensors are ideal for test and development applications including: Test and measurement Temperature mapping OEM applications How does a Thermocouple Work? A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables which is a process also known as the Seebeck Effect. What is a Welded Exposed Junction? An exposed junction is where the thermocouple wires are welded together but not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures Why RS PRO? RS PRO is our own brand range and brings you a wide range of high-quality, great value products offering you more choice. Trusted by engineers all over the world, every part of every RS PRO product has been rigorously tested against demanding industry standards they??re only given the RS PRO seal of approval if we??re confident of their exceptional quality, which means you can be confident too.