상품이미지
  •  상품이미지

MPN : XR-095-RS

RS PRO Type K Thermocouple 1m Length, 1/0.2mm Diameter ??+250°C
  • 브랜드

    RS PRO

  • 무원상품코드

    M010649006514

  • 타입별
    PK
  • 주문가능수량

    855

  • 최소주문수량5
  • 판매단위5
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 5개 ~ 5,543원

  • 수량단가2 : 30개 ~ 5,387원

  • 수량단가3 : 150개 ~ 4,433원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 RS PRO
제조사품명 XR-095-RS
간략설명 RS PRO Type K Thermocouple 1m Length, 1/0.2mm Diameter ??+250°C

■ 제품사양

Thermocouple
타입 = K Probe Diameter = 1/0.2mm Probe Length = 1m Maximum Temperature Sensed = +250°C Termination
타입 = Cable Cable Length = 1m Standards Met = BS RS Pro BS1843
타입 K ;
타입 T Exposed Junction Wire Thermocouple. From RS Pro type K and
타입 T thermocouple temperature sensors colour coded to the former British Standard ??BS1843-1952 with a Class 1 tolerance in accordance with IEC 584-2 (formerly BS4937:1983) standards for optimum accuracy. These thermocouple temperature sensors feature a welded tip exposed junction for a fast response time. The leads have a durable PTFE insulation for resistance to oils, acids and other fluids. How does a Thermocouple Work?. A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect. What is a Welded Exposed Junction?. In a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily. Features and Benefits. Welded, exposed junction for fast response times IEC-584-2 Class 1 tolerance for optimum accuracy Durable PTFE lead insulation for resistance to oils, acid, fluids and good mechanical strength and flexibility. Applications. Exposed junction thermocouples are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures. Applications for these
타입 K and
타입 T thermocouples include test and development, test and measurement, temperature mapping and OEM applications.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-05-27
3
답변 완료
2024-05-13
4
답변 완료
2024-04-16
5
답변 완료
2023-12-08
6
답변 완료
2023-11-21
상품정보이미지