MPN : 657-642-630

RS PRO Non Contact Voltage Indicator, 230V ac to 1000V ac
  • 브랜드

    RS PRO

  • 무원상품코드

    M010556010003

  • 타입별
    EA
  • 주문가능수량

    156

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 70,971원

  • 수량단가2 : 5개 ~ 58,408원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 RS PRO
제조사품명 657-642-630
간략설명 RS PRO Non Contact Voltage Indicator, 230V ac to 1000V ac

■ 제품사양

Indicator
타입 = Voltage Battery
타입 = AAA ATEX Approval = Yes Power Source = Battery Safety Category = CAT III 1000 V ac
무게 = 50g Diameter = 18mm Length = 151mm Maximum Detection Voltage = 1000V ac
최대 작동 온도 = +40°C
최소 작동 온도 = -20°C Only use with GP Alkaline GN24A, LR03, Size AAA. RS Pro Volt Stick Non-Contact Voltage Detector. The Non-Contact VoltStick® is a tester for safely checking the presence of an AC voltage without making any disconnections in cables, wall sockets, fuses, circuit breakers, junction boxes etc. No current flow is needed for correct detection. Apply the plastic tip to any connection point or move it along an insulated cable. When an AC voltage is detected a red indicator in the plastic tip illuminates, as it detects the live wire through the insulation. Note that if a 3 phase machine is connected up and one of the fuses blows, the voltage is conducted back to the defective fuse the other way and a faulty indication may be given. Make sure that all machines are disconnected before testing. The VoltStick® cannot be used on socket with shielded cable. Features and Benefits:. Voltage Range: 230 V ac - 1000 V ac Sensitivity: Illuminates red at 4 mm distance from wire carrying 230 V ac Power: 2 x AAA batteries (Included) Altitude: ; 2000 m RH: 80% @ 30°C, 50% @ 40°C Operating Temperature: -20°C to +40°C Over Voltage: CAT III 1000 V
무게: 50 gm Length: 151 mm Diameter: 18 mm IEC61010-1 CAT III 1000 V ac. Note. Only use with GP Alkaline GN24A, LR03, Size AAA. What is a non contact voltage tester used for?. Locating breaks in cables Detecting blown fuses inside plugs of fuse holders Distinguishing between live and neutral wires in both single and 3 phase supply Identifying faulty inline switches Checking function of circuit breakers Locating defective in-series light bulbs

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-11-01
2
신청 접수
2024-10-31
3
답변 완료
2024-10-24
4
신청 접수
2024-10-21
5
신청 접수
2024-05-27
7
답변 완료
2024-05-13
8
답변 완료
2024-04-16
9
답변 완료
2023-12-08
10
답변 완료
2023-11-21
상품정보이미지