상품이미지
  •  상품이미지

MPN : XQ-1460-RS

RS PRO Type T Thermocouple 1m Length, 1/0.3mm Diameter ??+250°C
  • 브랜드

    RS PRO

  • 무원상품코드

    M010518011057

  • 타입별
    EA
  • 주문가능수량

    745

  • 최소주문수량1
  • 판매단위1
  • 제품정보
  • 배송정보
    (영업일 기준)
  • 특이사항
구매수량 :

*대량구매해택
  • 수량단가1 : 1개 ~ 10,701원

  • 수량단가2 : 5개 ~ 10,515원

  • 수량단가3 : 25개 ~ 8,654원


총금액
(VAT 별도)
  • 상품정보
  • 상품후기
  • 상품문의
  • 배송/AS안내

■ 제품필수정보

제조사 RS PRO
제조사품명 XQ-1460-RS
간략설명 RS PRO Type T Exposed Junction Thermocouple 1m Length, 1/0.3mm Diameter → +250°C
문서자료 https://documents.rs-online.com/techlib:/itc_doclist_GB.htm?stockno=1236328

■ 제품사양

Thermocouple
타입 = T Probe Diameter = 1/0.3mm Probe Length = 1m Maximum Temperature Sensed = +250°C Termination
타입 = Miniature Plug Cable Length = 1m Standards Met = IEC RS Pro IEC
타입 T Exposed Junction Fast Response Thermocouple with Miniature Plug. From RS Pro a type T thermocouple temperature sensor conforming to IEC-584-3 standards with Class 1 tolerance. These thermocouple temperature sensors feature a welded tip exposed junction for a fast response time. The twin-twisted lead have a durable Teflon PFA insulation are are terminated with an IEC 584 colour code miniature flat pin plug for a quick and easy connection. How does a Thermocouple Work?. A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect. What is a Welded Exposed Junction?. A welded exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures. Features and Benefits. Welded, exposed junction for fast response times IEC-584-3 Class 1 tolerance for optimum accuracy Durable Teflon PFA lead insulation for resistance to oils, acid, fluids and good mechanical strength and flexibility Miniature flat pin plug for quick and easy connection Temperature range of -75 to +250°C. Applications. Exposed junction thermocouples are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures. Applications include test and development, test and measurement, temperature mapping and OEM applications.

순번
분류
제목
작성자
날짜
데이터 없음 ...
순번
답변 상태
제목
작성자
날짜
1
신청 접수
2024-05-27
3
답변 완료
2024-05-13
4
답변 완료
2024-04-16
5
답변 완료
2023-12-08
6
답변 완료
2023-11-21
상품정보이미지